DIGITAL TORQUE INDICATORS

  • Space Age Accuracy - made possible through advanced torque cell design and the latest in microprocessor technology.
  • Exclusive Clockwise/Counterclockwise Indication - the most precise indication and calibration offered in the industry.
  • Test Span and Display Test Circuits - for internal calibration and display segment testing.
  • Engineering Unit Selector Switch - A choice of lbs.-ft., lbs.-in., N-M and m-kg at the press of a button.
  • Digital Peak Hold - Provides an indication of the maximum torque applied during torque cycle.
  • Durable Steel Case - Rugged, heavy duty steel case with textured, two-tone brown epoxy finish with retractable front legs. Suitable for field use. (Optional handle available.)

TSD 1200

TSD 1201

TSD 6000
   
SPECIFICATIONS TSD 1200 - 1201 SPECIFICATIONS TSD 6000
Size:
4"h x 9"w x 9"d 11 1/2"h x 9 1/2"w x 7 1/8"d (9" with cable adapters)
Weight:
6.5 lbs 16 lbs single channel 18 lbs. multi-channel
Power:
115/220 VAC ± 10% 50/60 Hz 110/230 VAC ± 10%, 50/60 Hz - 20 watts RFI and EMI Filtered
Accuracy:
+0.01 0.01
Temp Range:
0 to 50ºC (32 to 125ºF) 0 to 50ºC (32 to 125ºF)
Display Blanking:
High intensity LED digits, 0.43 high 103% of full scale capacity
Resolution:
±10,000 counts external 50,000 counts internal Up to 20,000 graduations displayed
Features:
Push Button Zero, Peak Hold Push button zero, zero tracking, motion detection, display and system check, peak hold circut with manual and/or auto reset.  20 Mil mA Loop, RS232C(standard), bidirectional serial port
Options: Dual Digital Thumb Wheel Setpoint, Parallel BCD Output, Serial (RS232C/20ma) Output, Panel Mounting, Analog Output

TSD TORQUE TRANSDUCERS & CELLS 

  • TORQUE SPECIALTIES Div. designs and manufactures torque transducers to state of the art accuracy.
  • These advanced designs are easily adapted to a variety of torque applications.
  • The installation of these versatile torque transducers in reactive or absorbtive systems, in our torque loaders, multipliers, and test systems offer the user the ultimate in torque testing.
  • Our exclusive thru hole pin type transducer adapts to many applications where reaction measurements are desired. The .1 % accuracy makes this the choice for precision torque wrench and device calibration systems.
  • The square to square type is compact and accurate to .1 % f.s., can be used as a precision torque wrench or adapted into many of our torque test systems including our exclusive torque multiplier test systems enabling the user to measure the input and output simultaneously with unequalled ease and accuracy.
  • The shallow type may be base mounted for stand alone applications or adapted to mount onto a resident transducer on our torque loader wrench test systems.
  • The round shaft design may be manufactured to many sizes and configurations to fit specific requirements.
  • In addition to the above standard models, TORQUE SPECIALTIES Div. A.K.O. Inc. will design and build transducers to customer requirements and specifications.
FIGURE 1 FIGURE 2 FIGURE 3 FIGURE 4
FIGURE MODEL NO. LBS-FT A B C D E F WT
1
TSD011/20d12 20 LB.-IN.* .25 1.25 3.50 .25 2.875   3
1
TSD11/002 2 .25 1.25 3.50 .25 2.875   3
1
TSD11/005 5 .25 1.25 3.50 .25 2.875   3
1
TSD11 10 .25 1.25 3.50 .25 2.875   3
1
TSD11/020 20 .25 1.25 3.50 .25 2.875   3
1
TSD11/050 50 .38 1.25 5.00 .38 4.000   6
1
TSD111 100 .38 1.25 5.00 .38 4.000   6
1
TSD111/200 200 .38 1.25 5.00 .38 4.000   6
2
TSD511 500 .75 3.50 5.50 .750 3.750 .88 12
2
TSD1011 1000 .75 3.50 5.50 .750 3.750 .88 12
2
TSD2011 2000 .75 3.50 5.50 .750 3.750 .88 12
2
TSD2511 2500 .75 3.50 5.50 .750 3.750 .88 12
2
TSD4011 4000 .75 3.50 5.50 .750 3.750 .88 12
2
TSD6511 6500 .75 3.8 7.0 .750 5.0 1.0 16
2
TSD10011 10000 1.00 4.75 9.50 1.000 7.000 1.25 47
2
TSD20011 20000 1.00 4.75 9.50 1.000 7.000 1.25 47
2
TSD40011 40000 1.25 6.00 12.75 1.250 10.500 1.625 81
2
TSD80011 80000 2.00 8.00 15.50 1.5000 12.000 1.90 190
2
TSD100011 100000 2.00 8.00 15.50 1.5000 12.000 1.90 190
*All capacities are rated in lb.ft. but are all convertable in equivalent lb.in., Newton meters, Meter k.g., Etc.
FIGURE MODEL NO.
CAP
A
B
C
D
E
3 TSD20D12 20 LB.-IN. 1.00 1.50 .250 1.75
3 TSD100D12 100 LB.-IN. 1.00 1.50 .250 1.75
3 TSD0521 50 LB.-FT. 1.25 1.50 .375 1.88
3 TSD321 250 LB.-FT. 1.50 1.75 .500 2.25
3 TSD821 800 LB.-FT. 2.00 2.62 .750 3.38
3 TSD2012 2000 LB.-FT. 2.50 3.50 1.000 4.50
3 TSD4021 4000 LB.-FT. 3.50 4.50 1.500 6.00
3 TSD6521 6500 LB.-FT. 3.50 4.50 1.500 6.00
4 TSD054 50 LB.-FT. 1.25 1.50 .50 3.00 .781
4 TSD314 250 LB.-FT. 1.50 1.75 .75 3.00 .781
4 TSD814 800 LB.-FT. 2.00 2.62 1.00 3.00 .781
Check with our Engineering Dept. for other capacities or configurations
SPECIFICATIONS OF FIGURES 1 and 2
SPECIFICATIONS OF FIGURES 3 and 4
Excitation Voltage (recommended):
10-15 VDC
10-15 VDC
Input Resistance:
700 Ohms
700 Ohms
Output Resistance:
700 Ohms
700 Ohms
Nonlinearity:
0.05%
0.10%
Repeatability:
0.02%
0.05%
Hysteresis (Non-reversing):
0.03%
0.05%
Cell Accuracy (System):
0.1% F.S.
0.2% F.S.
Safe Overload:
150%
150%